Commercial · Bayside, Peninsula & CBD
Exit & Emergency Lighting Testing and Installation
Exit and emergency lights have to work the one time the power fails. In Victoria they need to be tested every six months, with results recorded in a logbook that your building surveyor or fire auditor can check.
- Free on-site quote
- No call-out fee on quoted work
- 12-month workmanship warranty
- REC 23657

Overview
Professional Exit & Emergency Lighting Services
Ensuring the safety of your staff, customers, and visitors is paramount for any commercial or public building. Exit and emergency lighting systems play a critical role in guiding people safely out of a building during a power outage, fire, or other emergencies. At Zap Electrical, we provide comprehensive exit and emergency lighting services designed to keep your premises safe, compliant, and prepared for any situation.
What’s included
- Installation of new exit signs and emergency fittings
- 6-monthly discharge testing to Australian Standard AS 2293
- Battery, lamp and fitting replacement where tests fail
- Compliance logbook kept up to date after every visit
- Written report you can pass to your manager or auditor
- Scheduled reminders so tests are never missed
Installation of Emergency Lighting Systems
Whether you are fitting out a new commercial space, upgrading an older building, or expanding your current premises, our experienced electricians can design and install a reliable exit and emergency lighting system tailored to your specific layout. We ensure all installations meet the strict requirements of Australian Standards (AS 2293), providing optimal visibility and clear guidance along all escape routes.
Routine Testing and Maintenance
Emergency lighting systems must be regularly tested to ensure they function correctly when needed most. Australian Standards require exit and emergency lights to undergo a 90-minute discharge test every six months. Our team provides thorough testing and maintenance services, checking battery backups, replacing faulty globes or entire units, and ensuring your system is fully operational. We also provide detailed compliance reports for your records.
Upgrades and LED Conversions
If your current emergency lighting system is outdated or frequently failing, it may be time for an upgrade. We specialize in converting older, energy-hungry emergency lights to modern, energy-efficient LED systems. LED emergency lights offer superior brightness, significantly longer lifespans, and reduced maintenance costs, making them a smart investment for any business.
Why Choose Zap Electrical for Emergency Lighting?
With years of experience serving commercial clients across Carrum Downs and surrounding areas, Zap Electrical is your trusted partner for all emergency lighting needs. We understand the importance of compliance and safety, and we take pride in delivering prompt, professional, and high-quality workmanship. Whether you need a brand-new installation, routine testing, or urgent repairs, you can rely on our fully licensed and insured electricians to keep your building safe and up to code.
Essential safety measures and who is responsible
In Victoria, exit signs and emergency lighting are essential safety measures under the building regulations. For most commercial buildings and apartment blocks, the building owner, often the owners corporation, has to keep them maintained and prepare an annual essential safety measures report. The occupancy permit or maintenance determination issued by the building surveyor sets out which measures apply to your building and how often they must be checked.
Fire auditors and council building inspectors can ask to see the records at any time, and gaps in the logbook are usually the first thing they notice. Tenants can carry obligations too, depending on the lease, so it is worth knowing who has agreed to what. Our role is to make sure the emergency lighting part of that picture is current: each test done on time, each failed fitting dealt with, and each result written up so whoever prepares the annual report has what they need without chasing anyone.
What happens during a six-monthly test
2 simulates a mains power failure. The normal supply to the emergency fittings is switched off, and every exit sign and emergency light has to stay lit on its own battery for at least the rated duration, which for most buildings is 90 minutes. At the end of that period each fitting is checked, and any that have dimmed, flickered or gone out are recorded as failures.
Fittings are also inspected for physical damage, missing diffusers, signs blocked by shelving or signage, and legends that have faded. Once the test is over, mains power is restored and the batteries start recharging, which takes many hours, so we avoid testing just before an evening event or late-night trading. The logbook entry records the date, the fittings tested, any failures and what was done about them, and the same detail goes into the report sent to you after the visit.
Choosing replacement signs, fittings and batteries
When the same fitting keeps failing, a new battery is not always the best answer. Older fluorescent exit signs and emergency battens draw more power, run hotter and wear out batteries sooner than current LED units. Replacing them with LED fittings usually means fewer failures at each test and fewer battery changes over the life of the building. In larger sites, some owners consider self-testing or monitored systems, where each fitting runs its own discharge test on a schedule and reports faults.
These reduce time on site, but they still need periodic checks and proper logbook records. Placement matters as much as hardware. Exit signs need to be visible along the path of travel, and stairwells, corridors and car park exits need enough light for people to move safely when the power is out. If walls, shelving or partitions have changed since the original fit-out, we flag any areas that now look under-covered and quote the fix.
Scheduling around tenants, staff and trading
Testing means switching off the mains to emergency circuits and walking every floor, so timing needs some thought. In apartment buildings, we give the building manager or owners corporation manager the date in advance so a notice can go up in the lobby and lifts. In shops, cafes and offices, testing is usually done early in the day so batteries have recharged well before closing time.
Where emergency fittings share circuits with general lighting, part of a building may go dark briefly, and we plan that with you rather than surprising staff or customers. For property managers looking after several buildings across the south-east, tests can be grouped into a regular rotation so each site comes up at a predictable time of year. Keys, access cards and entry to plant rooms, car parks and locked tenancies are arranged before the day, which means the whole building is covered in one visit and the logbook is complete.
Who it’s for
Who we do this for
Owners corporations
Common areas, stairwells and car parks kept tested and documented.
Property managers
One contact for every building on your books, with reports for each.
Business owners
Shops, offices and warehouses that need to stay compliant without the hassle.
How it works
- 01
Request a quote
Online or by phone. We aim to call back within the hour.
- 02
Free on-site visit
Eric assesses the job and talks you through options.
- 03
Clear written quote
Itemised, with no call-out fee on quoted work.
- 04
Job done + warranty
Tested, certified and covered for 12 months.
FAQ
Exit & Emergency Lighting questions
How often do emergency lights need testing?
Every six months, under AS 2293. Each test is recorded in the building's logbook.
What happens if a light fails the test?
We tell you which fittings failed and why, quote the replacement, and retest once fixed so the logbook is complete.
Can you take over testing from another contractor?
Yes. We review the existing logbook and fittings, then set up a schedule from there.
Do you test after hours?
We test during business hours by default. If testing will disrupt your tenants, talk to us about timing.
Who is responsible for emergency lighting in an apartment building?
Usually the owners corporation, because most exit signs and emergency lights in an apartment building sit on common property. The owners corporation manager typically arranges the six-monthly testing, keeps the logbook and includes the results in the annual essential safety measures report. If you are unsure what your building's maintenance determination requires, we can look at it with you during the first visit.
How long do emergency light batteries last?
It varies with the battery type, the fitting and how hot the space runs. Batteries in warm ceiling spaces or older fluorescent fittings tend to fail sooner than those in cooler, modern LED units. The six-monthly discharge test is what tells you when a battery can no longer hold the fitting for the full duration, so replacements are based on actual results rather than guesswork or a fixed calendar.
Do new exit signs come with a Certificate of Electrical Safety?
Yes. Installing or replacing emergency fittings is electrical work, and a Certificate of Electrical Safety is provided once the work is finished. New fittings are also tested and entered in the building's logbook at the same visit, so the record for each new sign or light starts complete rather than waiting for the next scheduled test.
Free quote
Get a quote for exit & emergency lighting
Free on-site quote
Eric comes out, looks at the job and gives you a clear written quote.
No call-out fee on quoted work
You only pay for the work you approve.
We aim to call back within the hour
During business hours, Mon–Fri 7:00am–5:00pm.
12-month workmanship warranty
Fully licensed and insured. REC 23657.

The person who quotes your job
is the person who does it.
Related services
Electrical Maintenance
Planned and routine maintenance for property managers, owners corps and businesses.
Commercial Electrician
Comprehensive electrical solutions for businesses, from fit-outs to routine maintenance and safety checks.
Office Fit-outs
Power, lighting and data for new and refurbished offices, shops and clinics.
Exit & Emergency Lighting by suburb
Bayside
Kingston
- Exit & Emergency Lighting Mordialloc
- Exit & Emergency Lighting Aspendale
- Exit & Emergency Lighting Aspendale Gardens
- Exit & Emergency Lighting Edithvale
- Exit & Emergency Lighting Chelsea
- Exit & Emergency Lighting Bonbeach
- Exit & Emergency Lighting Patterson Lakes
- Exit & Emergency Lighting Keysborough
- Exit & Emergency Lighting Parkdale
- Exit & Emergency Lighting Mentone
- Exit & Emergency Lighting Cheltenham
- Exit & Emergency Lighting Moorabbin
- Exit & Emergency Lighting Heatherton
- Exit & Emergency Lighting Dingley Village
- Exit & Emergency Lighting Braeside
- Exit & Emergency Lighting Waterways
- Exit & Emergency Lighting Carrum
Frankston & surrounds
Mornington Peninsula
Greater Dandenong
Melbourne CBD