Dandenong South holds some of the biggest buildings we work in: distribution centres, cold stores and manufacturing plants along Frankston–Dandenong Road, near EastLink, and around Abbotts Road and Greens Road. A single site can have a very large number of exit signs and emergency lights spread across warehouse floors, mezzanines, docks and attached offices. Every one needs a six-monthly test under AS/NZS 2293; we record each fitting in the logbook and quote failures promptly. The precinct is about 15 minutes from our base.

About our exit & emergency lighting service

Cold stores and freezer rooms

Batteries lose capacity in the cold, so emergency fittings in chillers and freezer rooms need to be rated for low temperatures, and even then they are among the first to fail a discharge test. Condensation at freezer doors also gets into housings that are not properly sealed.

We pay close attention to these areas at every visit, recommend fittings designed for cold environments, and check the exit signs on the inside of freezer doors are working, since staff working in a dark freezer need to find the way out quickly. Replacements are logged and certified the same day.

Large sites and shift work

Sites running two or three shifts cannot simply turn the lights off. We plan each test zone by zone with the site manager so production lighting stays on, and we carry out the discharge test in stages where the emergency circuits allow.

Every fitting is numbered against a site plan, which makes it easy to report failures by location and to track which areas keep causing trouble. Docks and forklift routes get extra attention, since fittings there are often struck and damaged. Mezzanine stairs and attached offices are tested in the same pass.

FAQ

Common questions

Can you test a site that operates around the clock?

Yes. We test one zone at a time during agreed periods, so the whole site stays lit and operating while each area completes its discharge test. The site manager signs off each zone before we move on.

What about self-testing emergency fittings?

Self-testing and monitored systems reduce manual checks but still need regular inspection and proper logbook records. We read the system's results, check faults on the floor and record everything, so the logbook matches the system.