Exit & Emergency Lighting · Carrum

Exit & Emergency Lighting in Carrum

  • Free on-site quote
  • No call-out fee on quoted work
  • 12-month workmanship warranty
  • REC 23657

In Carrum, emergency lighting work centres on the shops and cafes along the Nepean Highway, the newer buildings around the rebuilt station, and blocks of units in the streets towards the foreshore. These buildings sit close to the beach and the Patterson River, and the salty, windy air takes a toll on fittings near doors and outdoor areas. We test every exit sign and emergency light on a six-monthly cycle, keep the logbook up to date and watch for corrosion as we go. Our base is about 15 minutes away.

About our exit & emergency lighting service

Corrosion near doors and courtyards

Emergency fittings mounted above a rear door or in an open courtyard catch salt spray every time the wind swings around. Over a few years that shows up as rusted screws, cracked diffusers and green corrosion on the battery terminals, and a fitting that looked fine from the floor can fail the discharge test outright.

At each visit we open suspect fittings, clean or replace corroded parts, and recommend sealed, weather-rated units for the most exposed spots so they last longer between replacements. Every repair is written into the logbook against the fitting's location.

Highway shops and small unit blocks

Shops on the strip mostly have a few fittings each, and many owners would rather not close for a test. We work early, before the doors open, and keep disruption to the emergency circuits wherever the wiring allows.

Small unit blocks are similar: a handful of fittings in the entry, stairs and car park, managed by an owners corporation that needs a clear record each year. We test, report and quote replacements in writing, so the committee can approve repairs without a second visit. Fittings in open car parks near the beach are checked for corrosion along with the rest.

FAQ

Common questions

Why do our emergency lights keep failing even after new batteries?

Near the coast, corrosion inside the fitting is a common cause. If the terminals or circuit board are damaged, a new battery will not fix it, and replacing the whole fitting is usually the better option.

Can you test a few shops in the same building on one visit?

Yes. If several tenancies share a landlord or agent, we can test them together and send separate reports so each tenant or owner has their own record. Testing is done early so the shops open as normal.