Most homes across the Ballarto Road estates are young enough that the wiring itself is rarely the culprit. When a safety switch trips in a newer house, the cause is usually something plugged in or fixed outside: an alfresco heater, a pond pump, a garage fridge, a damaged lead. Out on the Skye acreage properties it is a different story, with long cable runs to sheds and pumps. Eric tests to find out which applies before recommending any work.

About our electrical fault finding service

Newer homes and appliance faults

Because estate homes have modern switchboards with several safety switches, a trip usually only affects part of the house, which narrows the search. We start by unplugging everything on that circuit and resetting it. If it holds, appliances go back one at a time until the culprit shows itself; if not, the fixed wiring is tested.

Outdoor ceiling fans, radiant heaters and weatherproof powerpoints in alfresco areas are checked for moisture, since wind can drive rain under the roof line. Garage fridges and freezers are another frequent cause, as their compressors age.

Sheds, pumps and private lines on acreage

On larger lots, a dead shed or a pump that stops working may be fed by a long underground cable or a private overhead line. Private lines are the property owner's responsibility in Victoria, and a sagging conductor, a leaning timber pole or a tree touching the line can cause intermittent faults. We test the supply at each outbuilding, inspect any private line, and give you a written account of what has failed and what it will take to fix. Bore and tank pumps on these properties are tested too.

FAQ

Common questions

Why does my alfresco heater trip the power when it rains?

Radiant heaters are usually mounted under the roof edge, where driving rain can reach the element or the connection box. Moisture on a hot element leaks current to earth and the safety switch trips. We test the heater, check its mounting and seals, and confirm it is on its own circuit.

Could a builder's defect cause faults in a new home?

It can, for example a cable nicked during construction or an outdoor fitting left unsealed. We test and document what we find. If it looks like a defect, the written findings give you something specific to take to the builder.