When a machine circuit trips in a Carrum Downs factory unit off Hall Road or Ballarto Road, production stops until someone works out why. Faults in industrial units have their own causes: a motor with failing windings, a lost phase, a variable speed drive leaking current to earth, or a switchboard connection that has loosened under years of vibration. Eric tests in a set order to narrow the cause quickly, and agrees with you which parts of the workshop can keep running while he works.

About our electrical fault finding service

Machinery and three-phase faults

A three-phase motor that hums but will not start, runs hot, or trips its protection may have lost one phase, through a blown fuse, a failed contactor or a loose terminal.

Variable speed drives and some welders put a small amount of current onto the earth by design, and on a circuit with an RCD that can cause trips that look random. We measure voltage on each phase, check contactors and isolators, and test motor insulation. Readings are recorded so you can see whether the machine or the supply is at fault.

Homes across the suburb

On the residential side, most houses date from the 1980s to the 2000s, plus newer estates. Faults here are rarely old wiring breaking down. More often it is an appliance, an outdoor fitting, or a switchboard with too few safety switches, so one fault cuts power to half the house.

We test the appliances and circuits to find the actual cause. If the board is part of the problem, we explain what an upgrade would change before quoting it. Split systems and EV chargers added since the house was built are also tested, since a new appliance on an old circuit is a frequent trigger.

FAQ

Common questions

Can you test our factory without shutting the whole unit down?

Usually, yes. Most testing is done one circuit at a time, so only the equipment on that circuit needs to stop. Where a full shutdown is needed, such as at the main switchboard, we plan it with you at the start or end of a shift.

Our complex's gate and car park lights have failed. Who do we call?

Common property in a strata factory complex is the owners corporation's responsibility, so the manager usually arranges the work. We can test the gate motor, lighting circuits and shared switchboard, and report to the manager in writing.