Generous post-war blocks give owners room for a studio, a shed or a big rear extension, and every one of those means more cable, often underground, often joined to an old board at the front of the house. When something stops working, the fault could sit anywhere along that path. With the wetlands close by and the bay on the other side, damp is a frequent factor. Eric works through it in order, from the switchboard outwards, so you are not paying for guesswork.

About our electrical fault finding service

Power to the studio or shed goes off

Underground cable to an outbuilding can be damaged by a garden stake, tree roots, or a conduit that has let water in at a poorly sealed pit. The symptom is often a sub-board in the studio that trips without warning, or lights out the back that dim when a heater starts.

We test the cable between the main board and the sub-board for insulation breakdown and voltage drop, then check each circuit inside the studio. If the underground run has failed, you get options in writing, including whether a new route avoids the problem.

Old front rooms, new back section

When the back of the house has been replaced and the front rooms kept, the new circuits are often fine while the original cabling in the front is not. A trip that seems to come from the new kitchen can actually start in a forty-year-old lighting circuit that shares the same safety switch.

We split the circuits apart at the board and test each one separately, so the old wiring and the new extension are judged on their own readings rather than lumped together. That matters in Edithvale homes where the front rooms are kept for their character and their cabling has never been tested.

FAQ

Common questions

Can damp weather really cause my power to trip?

Yes. Moisture in an outdoor powerpoint, a sensor light or an underground junction lets current leak away to earth, so the RCD does its job and cuts the supply. In low-lying streets the ground stays wet longer after rain, so these faults can hang around for days.

Will you need to dig up my garden?

Only if the testing shows the fault is in the buried section, and only once you have agreed. We locate the faulty section first, so if digging is needed it is limited to where the damage actually is.