On a big Mount Eliza block, the switchboard rarely feeds just the house. It may also supply a pool pump, a studio, a shed down the back and lighting along the drive, usually through circuits added one at a time over the years. When Eric opens a board like that, the first task is working out what every cable actually feeds. The replacement is then laid out around the whole property, with RCD protection on each circuit and space left for whatever you plan next.

About our switchboard upgrades service

Outbuildings, pools and long cable runs

Cables that cross the length of a garden to a studio or shed have to be sized for voltage drop, and many older runs were simply joined onto a spare fuse. A new main board gives each outbuilding its own correctly rated breaker.

Where a shed or pool house carries several circuits, it gets a small sub-board with local safety switches and an isolator. Pool pumps and heaters move onto dedicated protected circuits. Old feeds buried without conduit are tested before reconnection, and if the insulation readings are poor, the quote says so and offers a new route.

Adding a generator changeover at the same time

Big gums and exposed ridges make storm outages a fact of life on some streets. If a generator inlet has been on your list, replacing the board is the cheapest moment to add one.

The changeover switch is mounted beside the main switch, and the circuits it will run, such as the fridge, a few lights and the internet modem, are grouped together in the new layout so switching over in the dark is simple. The house stays isolated from the grid while the generator runs, which protects line workers as well as your appliances.

FAQ

Common questions

Our 1970s split-level has the board on the lower floor. Can it move?

It can, but moving a switchboard means extending or replacing the consumer mains and sometimes relocating the meter, which brings in your distributor. Often it is better to keep the position and improve access and lighting around it. Eric will go through both options on site.

Will a new board stop the lights dimming when the pool pump starts?

Sometimes. Dimming can come from a shared or undersized circuit, a loose connection or the supply itself. Giving the pump its own circuit usually helps, and we measure voltage under load during the quote so you know which cause you are dealing with.